Photoview - Photometric and Radiometric Data Management in the Visible, Horticultural and Radiometric (UV)
Batcher Plus new Feature
Litecalc – Lighting Desing Project in the Visible, Horticultural and Radiometric (UV) Fields
General
- Results display directly during the luminaire aiming phase (RealTimeCalc function with LiveGrid grids)
The grid can be:
- with horizontal illuminance values without a background – the grid illuminance values update automatically as you move the mouse pointer over one or more luminaires
- with horizontal illuminance values with a background – the grid illuminance values update automatically as you move the mouse pointer over one or more luminaires, and the background color changes according to the value reached
- with spots (false color) in which the grey levels update according to the level reached based on the light spots of each individual luminaire
- A function for sorting results in printouts has been added. Sorting is possible by:
- Calculation Type / Surface / Observer
- Calculation Type / Observer / Surface
- Surface / Zoom / Calculation Type / Observer
- Surface / Zoom / Observer / Calculation Type
Roads and Tunnels
- The extended TabR has been added for grazing light with fixtures installed less than 2 meters above the ground.
- The TabR for reflection factors were previously configured with a β angle between 0 and 180°, while the tgγ was configured between 0 and 12 (corresponding to a maximum angle of approximately 85°). These matrices (type C1, C2, R1, etc.) cannot be used for grazing light calculations
- The TabR extended TabR provides a more extensive tgγ between 0 and 20, allowing for angles of up to approximately 88°
Sport Plus
- The function for accessing and editing the project generated via Sport Plus has been activated
Printouts
- The index has been moved to the second page and the page numbering has been changed
- The management of the luminaire tables has been changed and graphical and functional improvements have been made to the printing of the various pages
BugFix
- Tunnel Plus – The energy saving curve according to UNI 11095-2021 did not correspond to the curve required by the standard
- Roads+Tunnels – The program randomly moved the luminaires exiting the Advanced Roads+Tunnels Project function when selecting the Calculations button.
- Roads+Tunnels – The program incorrectly displayed the orientation of luminaires with an inclination angle other than 0°°
- Emergency Plus – The program did not automatically add the selected luminaires to the emergency exits
How to update the program
To update the program, simply launch LITESTAR 4D and respond affirmatively to the update proposal by pressing the Download button